Health Assessment Criteria for Cable Lines beyond Rated Service Life
DOI:
https://doi.org/10.25729/esr.2026.02.0010Keywords:
Insulation degradation, oil-paper insulation, failure rate, health indexAbstract
The study focuses on the health assessment of 10 kV oil-paper insulated power transmission cable lines beyond their rated service life to assess the feasibility of their service life extension. The analysis examines various degradation factors, including thermal stresses from load and fault currents, as well as the impact of switching overvoltages and burn-down currents used for fault location. A health index calculation methodology is presented to evaluate the feasibility and potential duration of continued operation for cable lines.
References
A. N. Nazarychev, A. A. Andreyev, Methods and Models of Comprehensive Health Assessment of Power Equipment. Ivanovo, Russia: Ivanovo State Power Engineering University, 2005, pp. 111–125. (In Russian)
On the Non-Ignition Verification of Cables under Short-Circuit Current Conditions in Power Plant Auxiliary Systems, Circular NTs-02-98(E), Moscow, Russia: RAO UES, Mar. 16, 1998, pp. 1–12. (In Russian)
Electrical Network Regulations, 6th ed. Moscow, USSR: Energoatomizdat, 1987, pp. 16–42. (In Russian)
B. N. Neklepayev, Electrical Engineering of Power Plants and Substations. Moscow, USSR: Energoatomizdat, 1986, pp. 147–216. (In Russian)
G. S. Kuchinsky, V. E. Kizevetter, Y. S. Pintal, Insulation of High-Voltage Installations. Moscow, USSR: Energoatomizdat, 1987, pp. 285–328. (In Russian)
F. A. Likhachev, Ground Faults in Networks with Insulated Neutral and Capacitive Current Compensation. Moscow, USSR: Energiya, 1974, pp. 110–136. (In Russian)
R. Y. Fedosenko, F. A. Likhachev, Reliability of 6–10 kV Cable Lines. Moscow, USSR: Energiya, 1972, pp. 13–34. (In Russian)
M. A. Korotkevich, Key Areas for Enhancing the Operation of Electrical Networks. Minsk, Belarus: Tekhnoperspektiva, 2003, pp. 278–347. (In Russian)
Standards and Scope of Power Equipment Testing in the Belarus Power System, Belenergo Concern, Minsk, Belarus: Tydzen, 2000, pp. 167–182. (In Russian)
N. I. Voropai, Reliability of Power Supply Systems. Novosibirsk, Russia: Nauka, 2015, pp. 101–125. (In Russian)
V. G. Kitushin, Reliability of Energy Systems, part. 1. Novosibirsk, Russia: Novosibirsk State Technical University Press, 2003, pp. 124–165. (In Russian).
L. A. Daryan, V. P. Polischuk, A. V. Shurupov, “On the performance of transformer explosion protection systems,” Energoekspert, no. 4 (51), pp. 74–76, 2015. (In Russian)
L. A. Daryan, V. P. Polishchuk, A. V. Shurupov, Explosion Safety and Protection of High-Voltage Oil-Filled Equipment of Power Plants and Substations. Moscow, Russia: Prestizh ART, 2020, pp. 103–128. (In Russian)
Y. B. Guk, Fundamentals of Electrical Installation Reliability. Leningrad, USSR: Leningrad University Press, 1976, pp. 72–102. (In Russian)
V. A. Kaniskin, E. M. Kostenko, A. I. Tajibayev, “Non-destructive method for calculating the residual life of polymer-insulated electric cables,” Elektrichestvo, no. 5, pp. 19–23, 1995. (In Russian)
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Energy Systems Research

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.